LIMITED TIME ONLY for new customers: 15% off your first repair order!

Fanuc Spindle Amplifier Alarm 7, 07

FANUC Alarm Codes >> FANUC Spindle Amplifier Alarms >> Spindle Amplifier Alarm 7, 07

Disclaimer: Attempting repairs yourself can be dangerous and can void your warranty. Contact us for support.


FANUC Spindle Amplifier Alarm Codes 7, 07

Models AffectedDescriptionTroubleshooting

Fanuc 6055 digital spindle amplifiers
Fanuc 6063, 6064 serial spindle amps
Fanuc 6072, 6078, 6082, 6088, 6102 amps
Fanuc 6111, 6112, 6116, 6141, 6142 amps
Fanuc 6059, 6060 spindle amps
Fanuc 6044, 6052 analog spindle amps                                   

The motor rotates at a speed exceeding 115% (standard setting) of the maximum allowable speed.

  1. If this alarm is issued during spindle synchronization
    1. If the activation (SFR, SRV) of the motor on one side is turned off then back on the in the spindle synchronization mode, the spindle motor is accelerated to correct a position error built up during the period, thus causing this alarm. Modify the ladder so that SFR and SRV are not turned off in the spindle synchronization mode.
  2. If this alarm is issued while the motor is stopped
    1. The connection cable of the spindle sensor is faulty. Check if the cable of the spindle sensor built into the motor (BZ sensor when a built-in motor is used) is disconnected, and replace the cable as required.
    2. The spindle sensor built into the motor is not adjusted correctly. Adjust the sensor according to Subsection 4.3.4 of Part I.

 

Relevant 6044 analog spindle amplifiers to the 7 alarm:

Relevant 6052 analog spindle amplifiers to the 7 alarm:

Relevant 6055 digital spindle amplifiers to the 7 & 07 alarms:

Relevant 6059 digital spindle amplifiers to the 7 & 07 alarms:

Relevant 6060 digital spindle amplifiers to the 7 & 07 alarms:

Relevant 6063 serial spindle amplifiers to the 07 alarm:

Relevant 6064 digital spindle amplifiers to the 07 alarm:

Relevant 6078 digital spindle amplifiers to the 07 alarm:

Relevant 6082 digital spindle amplifiers to the 07 alarm:

Relevant 6088 digital spindle amplifiers to the 07 alarm:

Relevant 6102 digital spindle amplifiers to the 07 alarm:

Relevant 6111 spindle amplifiers to the 07 alarm:

Relevant 6112 spindle amplifiers to the 07 alarm:

Relevant 6116 spindle amplifiers to the 07 alarm:

Relevant 6141 spindle amplifiers to the 07 alarm:

Relevant 6142 spindle amplifiers to the 07 alarm:


Contact Tri Star CNC Services


How Tri Star CNC Can Help with FANUC Alarm Code 7, 07

Our servo error experts at Tri Star CNC can help you troubleshoot and provide solutions for your FANUC servo amp alarms. We offer FREE phone support with REAL humans, call 815-578-9145 and we’ll walk through the servo issue with you. If you need on-site support you can check out our field service network to find a service provider near you.

FANUC Parts Exchange, Repair, & Warranty

Send us your damaged FANUC parts, and our skilled technicians will check if they can be repaired. If they can't be fixed or you need a quick solution, you can order replacement parts from our exchange parts stock. All exchanged and repaired parts come with a 1-year warranty. Tri Star CNC covers the entire assembly repair, not just parts and labor.

Contact Tri Star CNC for further CNC machine support

Contact Us

For parts repair or replacement, please fill out the form below and we’ll get back to you as soon as possible.

upload pdf

* Indicates a Required Field
Call now for FREE phone support
FREE Phone Support
815-578-9145